Boiler Facts... George R. Carey, Jr. Vice President, Fluid Industrial Associates gcarey@fiainc.com twitter: @Ask_GCarey Adapting to the Changes in the Heating Industry… TThe landscape in the heating industry, with regard to residential and commercial boiler rooms, has drastically changed. Over the years, when you entered a typical boiler room in the Northeast, it was very common to find a sectional cast iron boiler or boilers and usually some type of indirect heating appliance for domestic hot water. It could be a side-arm heat exchanger with a storage tank or a storage tank with the heating coil installed directly inside. Nowadays, it has become quite common to find high efficiency modulating and condensing gasfired boilers (either LP or natural). These boilers are not your average “run of the mill” atmospheric gas boilers either, because their efficiencies range between 90% and 96%. They use a Neg/Reg gas valve and fan assembly, which means the amount of gas that flows into the burner for combustion is regulated by the fan assembly’s blower speed. The blower speed is controlled by an onboard micro-processor that is performing several internal calculations to determine the appropriate amount of British thermal units (BTUs) needed to satisfy the call. Hence the modulating part… it only uses the amount of gas necessary to satisfy whatever load it is currently “seeing.” Most of the residential models have a “turn down” ratio of 10 to one, meaning they can fire down to 10% of their total capacity and, of course, all the way up to 100% of their capacity. It has become quite common in larger residences to install two or more smaller modulating and condensing boilers that, when combined, can handle the home’s total load. However, more importantly during the normal course of the heating season when the home is operating at “part load,” the boiler plant consumes just the amount of energy needed to satisfy the current load the house is “seeing.” The same holds true for commercial applications such as apartment buildings, condominiums, churches and schools. The larger commercial modulating and condensing boilers also offer turn down ratios 10 to one. That means with a couple of commercial boilers, you can fire down to five percent of the total BTU capacity of the boiler plant. With this type of turn down, building owners are experiencing fuel savings in a range of 35%–40% and higher! Another unique feature with these boilers is the venting options. The blower motor is designed to not only bring combustion air into the burner assembly but also vent the residual products out of the building. Most of the modulating and condensing boiler manufacturers have approved their boilers to use several different vent materials. They are approved to be vented with PVC, CPVC, polypropylene and stainless steel vent pipe. Each manufacturer provides very detailed instructions on the “Do’s and Don’t’s” of how to properly vent their boilers. Following these instructions is critical to allow the boilers to operate efficiently. Of course, all of this piping needs to be sealed tight to meet the venting codes. These boilers encourage the condensing of their flue products, which is the exact opposite of traditional boilers. Their heat exchangers are designed to withstand the corrosive nature of the condensate that forms when the combustion products are condensed. This condensing action is where the additional efficiency points are obtained. Some of the by-products include condensation gathered in the boiler’s heat exchanger. If allowed to accumulate, it will negatively impact the boiler’s efficiency performance, which is why the manufacturers all suggest an annual inspection and cleaning of the heat exchanger, if necessary. Also, the venting should be inspected to make sure nothing has changed that could negatively impact the operation of the boiler. This means every “mod/con” boiler needs to be inspected every year. One of the oil industry’s shining stars has been their reputation for service and maintenance. The need for these high efficiency boilers to be maintained is a perfect opportunity for a company that has a service department to offer service contracts to home owners, commercial property owners and management companies. Most of the boiler manufacturers or their local representatives offer classes on servicing these new modulating and condensing boilers. What else? A new style of “smart” pump has been making its way into the North American hydronics mechanical rooms. These new circulators are called ECM pumps. ECM stands for electronically commutated motor and they are very different from the PSC (permanent split capacitor) motors we are used to with our wet rotor pumps. This new style motor is sometimes called a “brushless DC” motor. The rotor in this ECM motor has permanent magnets instead of wire windings that are separated from the system fluid. The magnets are located inside 18 ICM/July/August 2016


ICM July-August 2016
To see the actual publication please follow the link above